Search results for "Denture Retention"

showing 10 items of 15 documents

Retention strength of ball-attachment titanium post for removable partial denture or overdenture

2020

Aim: To evaluate the retention of an endodontic titanium post with a spherical head for removable partial denture or overdenture attachment according to surface treatment type. Methods: Sixty healthy single-rooted teeth, sectioned at the enamel/cementum junction, were treated endodontically and steadily fixed in the embedding acrylic resin. The titanium posts were subdivided into four groups: control, no surface treatment (Ctrl); posts with macro-retentive grooves (MR); air abrasion of the post surface (AB); and posts with macro-retentive grooves and air abrasion of the post surface (MR+AB). The posts were luted in the root canal using self-adhesive dual resin cement. Pull-out testing was p…

Materials scienceRoot canalDentistry03 medical and health sciences0302 clinical medicineSettore MED/28 - Malattie OdontostomatologicheSurface propertiesDentinmedicineAir abrasion dentalGeneral DentistryAcrylic resinDenture RetentionCementationCementUniversal testing machine030505 public healthEnamel paintbusiness.industryAir abrasion dental cementation. Denture retention. Surface Properties.technology industry and agricultureRK1-715030206 dentistrymedicine.anatomical_structurevisual_artDentistryvisual_art.visual_art_medium0305 other medical sciencebusinessDenture retentionRemovable partial dentureBrazilian Journal of Oral Sciences
researchProduct

Support of removable partial dentures in situations with a unilaterally missing canine and a curved edentulous ridge.

1997

The load and movement of abutments and removable partial dentures were examined in situations with a unilaterally missing canine and a curved edentulous ridge. These measurements were performed on a model adapted to intraoral conditions. In this simulation, removable partial dentures supported by incisors may result in failure. Spring rest support results in significantly reduced articulation vertically and horizontally when compared with solid rest support and avoids periodontal overloading.

Dental Stress AnalysisCuspidDenture BasesComputer sciencemedicine.medical_treatmentDentistryDental AbutmentsIncisorDental AbutmentsmedicineMaxillaHumansRest (music)OrthodonticsAnalysis of Variancebusiness.industryJaw Edentulous PartiallyRidge (differential geometry)Denture RetentionIncisormedicine.anatomical_structureDental Stress AnalysisDenture baseDenture Partial RemovableOral SurgeryDenturesbusinessThe Journal of prosthetic dentistry
researchProduct

Comparison of the retention strengths of three complete denture adhesives: An in vivo study

2009

One of the main problems posed by complete dentures is retention and stability. In order to solve this problem, dentists and the dental industry for a long time have attempted to improve denture adhesion by developing a range of "glues" of highly varied composition and efficacy. The present in vivo clinical study evaluates whether the adhesives used to improve complete denture retention are truly effective and able to increase denture adhesion to the mucosa covering the edentulous alveolar ridge.of the mandibular dentures. An in vivo clinical study is made of 30 patients with complete mandibular dentures to evaluate the retention afforded by three commercial complete denture adhesives (Benf…

OrthodonticsDenture Completebusiness.industrymedicine.medical_treatmentEdentulous alveolar ridgeDentistryOdontología:CIENCIAS MÉDICAS [UNESCO]Denture RetentionClinical studyOtorhinolaryngologyAdhesivesDenture adhesivesUNESCO::CIENCIAS MÉDICASMedicineHumansSurgeryDenturesbusinessGeneral DentistryDenture RetentionEdentulous patient
researchProduct

Effect of implant macro-design on primary stability: A prospective clinical study

2016

Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by…

AdultMaleInsertion torquemedicine.medical_specialtyTreatment outcomeDentistryOdontología02 engineering and technologyDental Prosthesis Retention03 medical and health sciences0302 clinical medicineDental Prosthesis DesignmedicineHumansProspective StudiesGeneral DentistryDental Implantsbusiness.industryResearchImplant design030206 dentistry:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyDenture RetentionCiencias de la saludSurgeryResonance frequency analysisDental Prosthesis DesignOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASProspective clinical studyFemaleSurgeryImplantOral Surgery0210 nano-technologybusinessDental Prosthesis RetentionMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

In vitro comparison of primary stability of two implant designs in D3 bone

2016

Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…

02 engineering and technologyIn Vitro Techniques03 medical and health sciences0302 clinical medicineHounsfield scaleBone qualityMedicineAnimalsGeneral DentistryOrthodonticsDental Implantsbusiness.industryResearchSignificant differenceImplant designDental Implantation Endosseous030206 dentistry021001 nanoscience & nanotechnologyImplant stability quotient:CIENCIAS MÉDICAS [UNESCO]Denture RetentionResonance frequency analysisOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral Surgery0210 nano-technologybusiness
researchProduct

A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years.

2014

Abstract Statement of problem Because of the high mechanical strength of zirconium dioxide, the metal in fixed partial prostheses can now be replaced. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Purpose The purpose of this prospective study was to evaluate the survival (without failure) and success (survival without any complication or failure) rate and clinical efficacy of anterior zirconia partial fixed dental prostheses. Material and methods Twenty-seven anterior partial fixed dental prostheses of 3 to 6 units were fabricated. All participants were examined after 1 month and 6 months, then annually for 7 years. Resu…

Dental Restoration FailureAdultMaleSurface Propertiesmedicine.medical_treatmentDentistryDental CariesProsthesisProspective evaluationAnterior regionDental MaterialsRecurrencemedicineHumansDental Restoration FailureProspective StudiesProspective cohort studyDenture DesignSurvival rateAgedbusiness.industryPeriapical DiseasesMiddle AgedDental PorcelainDenture RetentionSurvival AnalysisDental VeneersTreatment OutcomeComputer-Aided DesignDenture Partial FixedVeneerFemaleZirconiumOral SurgerybusinessComplicationFollow-Up StudiesThe Journal of prosthetic dentistry
researchProduct

In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®

2018

Background It is necessary to know the in vitro behavior of different attachment systems to be used clinically. The evolution of retention capacity over 10 years (14,600 insertion/de-insertion cycles) was determined in vitro, evaluating two overdenture attachment systems (Locator® and OT Equator®). Material and methods The study used an implant replica compatible with the abutments of both systems. 10 Locator® and 10 OT Equator® attachments were screwed to the abutments. Nylon inserts were attached and tested, subjecting them to 14,600 insertion and de-insertion cycles (representing 10 years functional life) in axial direction. The universal test machine crosshead speed was 50 mm/min with a…

Orthodontics03 medical and health sciencesProsthetic Dentistry0302 clinical medicineMaterials scienceResearchRetention capacity030206 dentistryImplantMandibular prosthesis implantationGeneral DentistryDenture Retention030217 neurology & neurosurgeryJournal of Clinical and Experimental Dentistry
researchProduct

The Randomized Shortened Dental Arch Study

2012

The scientific evidence concerning prosthodontic care for the shortened dental arch (SDA) is sparse. This randomized multicenter study aimed to compare two common treatment options: removable partial dental prostheses (RPDPs) for molar replacement vs. no replacement (SDA). One of the hypotheses was that the follow-up treatment differs between patients with RPDPs and patients with SDAs during the 5-year follow-up period. Two hundred and fifteen patients with complete molar loss in one jaw were included in the study. Molars were either replaced by RPDPs or not replaced according to the SDA concept. A mean number of 4.2 (RPDP) and 2.8 (SDA) treatments for biological or technical reasons occur…

AdultChange over timeMolarmedicine.medical_treatmentDentistryDental Abutmentslaw.inventionTooth LossDental ArchRandomized controlled triallawmedicineDenture Precision AttachmentHumansBicuspidProspective StudiesDenture DesignGeneral DentistryObservation timebusiness.industryJaw Edentulous PartiallyTreatment optionsDenture RetentionMolarDental archTreatment Outcomemedicine.anatomical_structureMulticenter studyDenture Partial RemovableProsthodonticsbusinessFollow-Up StudiesJournal of Dental Research
researchProduct

Five-Year Study of Implant Placement in Regenerated Bone and Rehabilitation With Telescopic Crown Retained Dentures: A Case Report

2009

Abstract Various implant-supported restorations have been used successfully for several decades to rehabilitate edentulous patients. Telescopic crowns are a common treatment modality used to connect dentures to natural teeth. Although previous findings indicate that telescopic crowns can be placed successfully on implants to support overdentures, only limited data are available on this treatment approach. Eight months after extraction of all nonsalvageable teeth and socket preservation, 11 implants were inserted into the mandible and maxillae of one patient. These implants were restored 4 months later using telescopic crown–supported dentures. Bleeding on probing (BOP), plaque index (PI), c…

AdultMalemedicine.medical_treatmentBleeding on probingAlveolar Bone LossDentistryDental AbutmentsCrown (dentistry)stomatognathic systemDental AbutmentsPeriodontal Attachment LossmedicineHumansTooth SocketDenture DesignDental alveolusDental ImplantsOrthodonticsSocket preservationDenture Completebusiness.industryDental Plaque IndexDental prosthesisDenture OverlayDenture RetentionMaxillaChronic PeriodontitisGuided Tissue Regeneration PeriodontalDental Prosthesis Implant-SupportedPeriodontal IndexOral SurgeryDenturesmedicine.symptomGingival HemorrhagebusinessFollow-Up StudiesJournal of Oral Implantology
researchProduct

Patient-centered and clinical outcomes of mandibular overdentures retained with the locator system: A prospective observational study

2017

Whether clinical or demographic variables affect the perception of treatment in terms of quality of life and satisfaction is unknown.The purpose of this prospective study was to make an evidence-based assessment of the treatment outcomes (patient- and clinically based) of locator-retained mandibular overdentures.This prospective observational study assessed patients with edentulism who had worn mandibular overdentures supported by 2 implants and retained by the locator system for at least 1 year of functional life (N=80). Medical histories were reviewed, and patients underwent oral examinations. Prosthetic clinical outcomes and patient well-being were registered using the Oral Health Impact…

Malemedicine.medical_treatmentDenture Complete LowerDentistryOral HealthMandibleAffect (psychology)Prosthesis03 medical and health sciences0302 clinical medicinePatient satisfactionQuality of lifeSurveys and QuestionnairesDenture RebasingHumansJaw EdentulousMedicineProspective StudiesDenture DesignProspective cohort studySurvival analysisAgedDental ImplantsEdentulismbusiness.industry030206 dentistryDenture Overlaymedicine.diseaseDenture RetentionSurvival Analysisstomatognathic diseasesTreatment OutcomePatient SatisfactionSpainQuality of LifeFemaleObservational studyDental Prosthesis Implant-SupportedOral Surgerybusiness030217 neurology & neurosurgeryFollow-Up StudiesThe Journal of Prosthetic Dentistry
researchProduct